Profile Selection
AngleLock profiles are available in multiple cross-section sizes. Select based on the load-bearing requirements:
- 30×30mm: Light-duty frames, guards, and enclosures (up to 50 kg/m)
- 40×40mm: General-purpose machine frames (up to 150 kg/m)
- 45×45mm: Medium-duty frames and workstations (up to 250 kg/m)
- 60×60mm: Heavy-duty structures and bases (up to 500 kg/m)
- 80×80mm: High-load machine bases and gantries (up to 1000 kg/m)
Connection Layout Planning
Plan connections at every joint where members meet. AngleLock connections work at 90-degree intersections (butt joints, corner joints, and T-joints). For angled connections, use the adjustable angle connectors. Minimize cantilever lengths by adding support members where loads are applied. For tall structures, add lateral bracing to prevent sway.
Deflection Verification
Calculate beam deflection to ensure the frame meets accuracy requirements. For a simply supported beam with center load: δ = FL³/(48EI), where F is the load, L is the span, E is the elastic modulus (70 GPa for aluminum), and I is the moment of inertia from the profile datasheet. Keep deflection under L/1000 for general machine frames or L/5000 for precision applications.
Example: 40×40mm profile (I = 8.64 cm⁴) with 1000mm span and 500N center load: δ = 500 × 1000³ / (48 × 70000 × 86400) = 1.72mm. For L/1000 = 1.0mm requirement, upgrade to 45×45mm or add center support.Typical applications