Pressure decay is the most common production leak test. Pressurize the part, close it off from the supply, and watch for a pressure drop over the test window.

Bravo Automation Technologies is an authorized distributor of LeakMaster leak detection systems and serves customers in the Upper Midwest (North Dakota, South Dakota, Iowa, Missouri, Illinois, Minnesota, Indiana, Wisconsin and Michigan). Browse the LeakMaster product page.

LM-AN-001LeakMaster EngineeringJanuary 2024

Overview

Drop more than the reject threshold and the part leaks. The method is simple. Getting repeatable results out of it is not, and that comes down to knowing what actually moves the measurement.

Test Theory

The pressure decay rate is related to the leak rate by the Ideal Gas Law. For a fixed test volume at constant temperature:

  • Leak rate (scc/min) = (ΔP × V) / (Patm × t) where ΔP is pressure change, V is volume, t is time
  • Smaller test volumes provide higher sensitivity (less air to lose)
  • Higher test pressures increase sensitivity proportionally
  • Longer test times allow smaller leaks to be detected
  • Typical sensitivity: 10⁻² to 10⁻⁴ scc/min depending on conditions
For air at standard conditions: Q (scc/min) = (ΔP × V) / (14.696 × t) where ΔP is in PSI, V is in cc, and t is in minutes. A 0.001 PSI drop in 100cc over 10 seconds = 0.041 scc/min leak rate.

Test Cycle Phases

A pressure decay test runs in four phases: Fill (pressurize the part), Stabilize (let pressure and temperature settle), Test (measure the change), and Exhaust (vent it). Stabilize is the one that trips people up. Cut it short and thermal effects either hide a real leak or invent one that isn't there, so the result is wrong either way.

Factors Affecting Accuracy

Temperature is the biggest source of error. A 0.1°F swing in a 100cc volume at 30 PSI shows up as a pressure change the size of a real leak. Other culprits: adiabatic heating during fill (compressed air heats up), moisture evaporating off the surface, and flexible parts flexing under pressure.

Typical applications

  • Automotive component testing
  • Medical device seal verification
  • Consumer product waterproofing
  • HVAC component testing

Related products

LM-Series Instruments • Sentinel Series. See them on the LeakMaster page or ask us for a quote.

View the original resource

Tell us what you are building

We will help you pick the right LeakMaster part and quote it.