Overview
Picking one means weighing how small a leak you have to catch against cycle time, cost, and the part itself. LeakMaster instruments run several methods, so one box covers most of what a production line throws at it.
Method Comparison
The four primary production leak test methods, ranked by typical sensitivity:
- Mass Flow: 10⁻³ to 10⁻⁵ scc/min — measures actual flow to maintain pressure
- Differential Pressure: 10⁻³ to 10⁻⁵ scc/min — compares test part against reference
- Pressure Decay: 10⁻² to 10⁻⁴ scc/min — measures pressure drop in isolated volume
- Vacuum Decay: 10⁻² to 10⁻⁴ scc/min — same as pressure decay but under vacuum
When to Use Each Method
Pressure decay handles general-purpose testing where sensitivity needs are moderate and the fixturing is simple. Reach for mass flow when you want a direct leak rate in scc/min, or when test volumes run large. Differential pressure earns its keep when ambient temperature swings would throw off a plain decay test. Vacuum decay is for parts you cannot pressurize from the inside.
Part Characteristics to Consider
The part drives a lot of this. Rigid parts (metal castings, plastic housings) work with any method. Flexible parts (bags, tubing) can balloon under pressure, so drop the test pressure or go vacuum. Porous materials usually need a sealant or special fixturing. Large internal volumes need longer test times, or a mass flow method to keep sensitivity up.
Typical applications
- Production line test planning
- Quality engineering specifications
- Test method validation
- Leak test process improvement
Related products
LM-Series • Sentinel Series • Custom Test Systems. See them on the LeakMaster page or ask us for a quote.