Overview
The forcer rides along a stationary shaft on a magnetic field, so there's no backlash and no parts wearing against each other. Positioning gets down to the micron, and the resolution you can hold depends on the encoder, not the motor. Sizing is where it goes right or wrong: the motor has to make your force at your speed with margin left over.
Force Requirements
Add up every force the motor has to overcome:
- Payload weight (for vertical applications: F = m × g)
- Acceleration force (F = m × a for the desired acceleration)
- Friction force from bearings, seals, and cable carriers
- Process force (pressing, dispensing, probing, etc.)
- Add 30% safety margin for peak force requirement
Speed and Resolution
These motors run anywhere from microns per second for slow scanning up to more than 1 m/s when you need throughput. Resolution comes from the encoder, not the motor, so with a fine enough encoder you can hold sub-micron. Pick the motor on its continuous force at your operating speed, straight off the force-speed curve in the datasheet.
Resolution = encoder pitch / (4 × interpolation factor). Example: 20µm pitch encoder with 256× interpolation = 20 / 1024 = 0.0195µm (19.5nm) resolution.Thermal Considerations
The forcer coils heat up under load, and that heat is what caps the continuous force rating. For high continuous force, use a larger forcer assembly or add external cooling. The shaft carries no windings, so it stays cool. That matters when the motor sits near temperature-sensitive parts.
Typical applications
- Precision pick-and-place
- Optical inspection scanning
- Microelectronics assembly
- Laboratory sample handling
Related products