Nanometer positioning is a whole-system problem. Every part (motor, bearing, feedback, structure, controller) has to be built to keep error down, because any one of them can blow the budget on its own.

Bravo Automation Technologies is an authorized distributor of PBA Systems direct drive linear motors and linear stages and serves customers in the Upper Midwest (North Dakota, South Dakota, Iowa, Missouri, Illinois, Minnesota, Indiana, Wisconsin and Michigan). Browse the PBA Systems product page.

PBA-AN-003PBA Systems EngineeringAugust 2024

Overview

PBA Systems ironless linear motors give you the zero-cogging, smooth motion to start from, but the motor alone won't get you there.

Error Budget Analysis

Set the accuracy you need first, then budget an error allowance to each subsystem:

  • Motor cogging and force ripple (< 0.5% for ironless)
  • Encoder/feedback resolution and accuracy
  • Bearing straightness and runout
  • Structural compliance and thermal drift
  • Controller quantization and servo bandwidth
  • Environmental vibration and acoustic noise

Feedback Selection for Nanometer Accuracy

Laser interferometers get you the best accuracy (sub-nanometer) but they're pricey and fussy about their environment. Optical encoders with interpolation (Heidenhain, Renishaw) hit practical nanometer resolution for a lot less. Under 10nm, look at laser encoders or capacitive sensors, which give you high resolution and high bandwidth at the same time.

Encoder noise floor ≈ resolution / √(12) for quantization noise. Example: 1nm resolution encoder has ≈ 0.29nm RMS noise floor. Actual noise includes interpolation errors, typically 2-5nm peak-to-peak for high-quality encoders.

Environmental Control

At these scales the environment runs the show. Steel expands 12µm/m/°C, so a 0.001°C swing drifts you 12nm per mm of structure. You need vibration isolation, passive or active. Acoustic noise off fans, pumps, and HVAC can ring structural resonances too. Enclose the system, or put it in a controlled room.

Typical applications

  • Semiconductor metrology
  • Atomic force microscopy stages
  • Optical alignment systems
  • Precision manufacturing inspection