Overview
CME 2 (Copley Motion Explorer 2) is the tool you use to configure and tune Copley drives. The setup runs in order: motor configuration, feedback, then the current, velocity, and position loops.
Initial Connection
CME 2 connects over RS-232, CANopen, or EtherCAT. It finds connected drives on its own and shows the current configuration. Before you change anything, read the drive's existing settings and save a backup — it's the fastest way back if a change goes wrong.
Motor Configuration
Get the motor parameters right or nothing downstream tunes well. The ones that matter:
- Motor type (brushless, brush, stepper)
- Pole count for brushless motors
- Continuous and peak current ratings
- Winding resistance and inductance
- Back-EMF constant (Ke)
- Torque constant (Kt)
Servo Loop Tuning
Copley drives use cascaded loops: current innermost, velocity in the middle, position outermost. Tune them in that order, inside out:
- Current Loop - Typically auto-tuned based on motor parameters
- Velocity Loop - Adjust Kp and Ki for desired bandwidth and stability
- Position Loop - Configure Kp, Kd, and Kff for accurate positioning
The velocity loop transfer function is: G(s) = Kp + Ki/s. Position loop uses: G(s) = Kp + Kd*s + Kff (feedforward).Auto-Tuning
CME 2 can auto-tune the gains for you. It injects test signals, watches how the system responds, and works out gain values from that. On demanding axes you'll usually still hand-tune from there.
Typical applications
- Initial drive commissioning
- Motor replacement and reconfiguration
- Performance optimization
- Troubleshooting and diagnostics
Related products
All Copley servo drives. See them on the Copley Controls page or ask us for a quote.