Application Notes / Copley Controls / EtherCAT Network Configuration Guide

Communications

EtherCAT Network Configuration Guide

Setting up Copley drives on an EtherCAT network: topology, ESI files, PDO mapping, and Distributed Clocks.

Bravo Automation Technologies is an authorized distributor of Copley Controls servo and stepper drives and serves customers in the Upper Midwest (North Dakota, South Dakota, Iowa, Missouri, Illinois, Minnesota, Indiana, Wisconsin and Michigan). Browse the Copley Controls product page.

AN-015Copley Controls EngineeringDecember 2023

Overview

EtherCAT (Ethernet for Control Automation Technology) is the fastest of the industrial Ethernet protocols for motion, with sub-microsecond synchronization and multi-axis cycle times under 1 ms. This note runs from the hardware wiring through commissioning a Copley drive on the network.

Network Topology

EtherCAT runs as a daisy chain, where each slave reads and writes its data as the frame passes through it. Copley drives have two RJ-45 ports for that:

  • Connect master to first drive Port In, first drive Port Out to second drive Port In, etc.
  • Maximum 65,535 slaves per segment (typically limited by cycle time requirements)
  • Cable length up to 100m between devices (standard Ethernet Cat5e/Cat6)
  • Ring topology supported for redundancy when master supports it

ESI File Installation

The EtherCAT Slave Information (ESI) file tells the master what the drive can do. Grab the current Copley ESI file from copleycontrols.com and load it into your master's config tool, whether that's TwinCAT, CODESYS, or Acontis. It defines the available PDO mappings, the supported modes, and the drive parameters.

PDO Mapping Configuration

Process Data Objects (PDOs) are the data that moves every cycle. Copley drives let you configure both the RxPDO (master→drive) and the TxPDO (drive→master). The standard DS402 mappings come preconfigured, and you can build custom ones when an application needs them:

  • Standard mapping: Controlword, Target Position, Statusword, Actual Position
  • Add velocity, torque, or I/O data as needed
  • Maximum PDO size depends on drive model
  • Configure via SDO during Pre-Operational state

Distributed Clocks

EtherCAT Distributed Clocks (DC) lock every drive to one time base to within a microsecond. Turn on DC Sync0 for the synchronized cyclic modes (CSP, CSV, CST). During startup the master measures the propagation delay to each slave and trims its clock to match.

Typical applications

  • Multi-axis EtherCAT systems
  • High-speed synchronized motion
  • TwinCAT and CODESYS integration
  • New EtherCAT network commissioning

Related products

Xenus Plus • Accelnet Plus • M-Series • Stepnet (STX). See them on the Copley Controls page or ask us for a quote.

View the original resource

Tell us what you are building

We will help you pick the right Copley Controls part and quote it.